The maximum output voltage in series is double of independent’s, and the maximum output current in parallel is double too. The two outputs can be connected in parallel or in series, while the master used for voltage or current adjustment. In a constant voltage state, the output voltage can be arbitrarily from 0 V on the nominal range and in the state of constant current, the output current can be adjustable from 0 A on the nominal range. The two adjustable outputs can also be selected for constant voltage or constant currant, designed in high stability and performance circuit. IntroductionĦ060 high-precision DC regulated power supply has two ways adjustable output. Ensure that no water gets inside the equipment to prevent possible shorts and damage to the equipment. Prior to cleaning the cabinet, withdraw the mains plug from the power outlet.Ĭlean only with a damp, soft cloth and a commercially available mild household cleanser. Measuring instruments don’t belong to children’s hands.
Opening the equipment and service – and repair work must only be performed by qualified service personnel. Do not store the meter in a place of explosive, inflammable substances. The meter is suitable for indoor use only. Periodically wipe the cabinet with a damp cloth and mid-detergent. Do not operate the meter before the cabinet has been closed and screwed safely as the terminal can carry voltage. Allow the equipment to stabilize at room temperature before taking up measurements (important for exact measurements). Do not subject the equipment to shocks or strong vibrations. Do not operate the equipment near strong magnetic fields (motors, transformers, etc.). Do not place water-filled containers on the equipment (danger of short-circuit in case of knock over of the container). Do not insert metal objects into the equipment by the way of ventilation slots. Do not cover the ventilation slots of the cabinet to ensure that air is able to circulate freely inside. Comply with the warning labels and other info on the equipment. To avoid electric shock, do not operate this product in wet or damp conditions.Ĭonduct measuring works only in dry clothing and rubber shoes, i. Do not exceed the maximum permissible input ratings. Replace a defective fuse only with a fuse of the original rating. Do not subject the equipment to direct sunlight or extreme temperatures, humidity or dampness. Do not place the equipment on damp or wet surfaces. Connect the mains plug of the equipment only to a mains outlet with an earth connection. Prior to connecting of the equipment to the mains outlet, check that the available mains voltage corresponds to the voltage setting of the equipment.